● VGRID POWER |Microgrid solutions and core equipment
Microgrid AC Cabinet MPS
Microgrid AC Cabinet MPS

SP750H54PSTD Integrated Cabinet

At a glance

SP750H54PSTD integrated cabinet integrates PCS, EMS, isolation transformer, and AC/DC power distribution units, with a rated power of 750kVA, supporting grid, diesel generator, battery, and PV connections, IP54 high protection, suitable for emergency power supply, diesel-storage, construction sites and other scenarios, and supports multi-cabinet parallel operation.

Key Features

  • Integrated internally with PCS, EMS, isolation transformer, and AC/DC power distribution unit
  • Configurable external STS with switching time ≤20ms
  • Supports grid, diesel generator, and battery connection, with built-in PV connection switch
  • Charging efficiency greater than 99.3%, supports multi-channel DC coupling
  • IP54 high protection rating, suitable for various application scenarios
  • Supports multi-cabinet parallel connection, ALL IN ONE plug and play

Specifications

ModelSP750H54PSTD
Maximum battery voltage950V
Minimum battery voltage680V
Rated battery voltage range680V-900V
Maximum battery current200A*6
AC side (grid-tied) rated power750kVA
AC side (grid-tied) rated current1086A
AC side (grid-tied) rated grid voltage400V/230V
AC side (grid-tied) grid voltage range-20%~15%
AC side (grid-tied) grid unbalance125%
AC side (grid-tied) grid frequency range50Hz/47Hz~52Hz(60Hz/57Hz~62Hz)
AC side (grid-tied) current harmonics<3% (above 30% load)
AC side (grid-tied) power factor-1~1
AC side (off-grid) rated output power750kVA
AC side (off-grid) maximum output power825kVA
AC side (off-grid) rated output current1086A
AC side (off-grid) maximum output current1194A
AC side (off-grid) rated voltage400V/230V
AC side (off-grid) output voltage harmonics<3% (resistive load)
AC side (off-grid) unbalance100%
AC side (off-grid) frequency range50/60Hz
Output overload (current) Ie*1.1<Iload≤Ie*1.25100s
Output overload (current) Ie*1.25<Iload300ms
EMS functionsSOC balancing, peak shaving and valley filling, self-consumption, surplus power to grid, cloud platform, anti-backflow, diesel-solar hybrid
Isolation transformerBuilt-in isolation transformer
Protection ratingIP54
DimensionsW*H*D=1200*2018*1227
Temperature range-30~60℃ (derating above 45℃)
Humidity range10-95%
Cooling methodAir cooling
Altitude4000m (derating above 2000m)
Transformer modelThree-phase isolation transformer
Transformer input rated voltage400V
Transformer input rated current1082.6A
Transformer input rated power750KVA
Transformer input operating frequency50/60Hz
Transformer output rated voltage400V
Transformer output rated current1082.6A
Transformer output rated power750KVA
Transformer output operating frequency50/60Hz
Transformer efficiency≥98.5%
Transformer noise≤65dB
Transformer weight1514Kg±5%

Product FAQ

What scenarios is the SP750H54PSTD integrated cabinet mainly used in?

It is mainly used in scenarios such as emergency power supply, diesel-storage, and construction sites, and supports multiple cabinets in parallel. What is the grid-connected/off-grid switching time? Seamless grid-connected/off-grid switching is ≤20ms, which requires an external STS. What are the product's protection rating and cooling method? The protection rating is IP54, and the cooling method is air cooling. Does it support remote upgrades and diagnostics? The supporting EMS supports remote OTA, can remotely diagnose EMS and inverter faults, and remotely upgrade software. Does it support OEM/ODM?

Not sure this is the right specification?

Send us your drawing, data sheet or sample and our engineers will confirm the match within 48 hours.

Request a Quote

Application Cases & Scenarios

View all →