Equipment selection
Equipment selection
Equipment selection

Equipment selection

VGRID POWER equipment selection guide: matching PCS, STS, all-in-one cabinets and hybrid inverters to power, topology and application.

Technical articles

LEONA-B750K vs LEONA-H135K: choosing between 750 kVA cabinet and 135 kVA wall-mount units

Both split hybrid inverters share the same VSG grid-forming core, PQ/VF/droop modes and LEONA-M200K MPPT platform, yet they differ in power class, battery voltage window, isolation and installation. The B750K is a 750/825 kVA IP54 floor cabinet with a built-in Znyn0 transformer; the H135K is a 135/148.5 kVA IP65 wall unit of about 85 kg. Start with the continuous load, the battery cluster voltage and the site lifting conditions.

Selecting the LEONA-M200K MPPT: 200 kW, 16 inputs and a 200-900 V tracking window

The LEONA-M200K is the external MPPT controller shared by the B750K and H135K: 200 kW rated, 200-1000 V PV open-circuit, 200-900 V MPPT range, 16 PV inputs across 8 MPPT channels and 99.26% peak efficiency. It decouples PV voltage from battery voltage and can be mounted near the array to shorten DC cabling. Check string temperature correction, input current and the high-voltage bus range together.

Reading the LEONA-B375K single-line diagram: 3 x 125 kW, a 400 kVA transformer and one-cluster-one-management

The LEONA-B375K IP54 cabinet integrates three SP125HCPS 125 kW converters, a 400 kVA isolation transformer, an STS, DC busbars, the EMS and every breaker in one enclosure. The system is rated 375 kW at 400 V/50 Hz with transfer below 20 ms. The point of the single-line diagram is not summing power ratings but seeing where battery clusters, breaker numbers and critical loads attach to the bus.

Choosing a built-in isolation transformer: Znyn0, neutral and critical-load supply

The LEONA-B750K carries a Znyn0 isolation transformer, the LEONA-B375K single-line diagram places a 400 kVA transformer TR between the AC bus and the STS, while the LEONA-H135K uses a lightweight wall-mount design without one. Isolation is not only about noise: it decides whether the neutral is independent, whether poor site earthing is tolerable, and which bus section feeds critical loads during transfer.

Topology choices for retrofit PV: AC coupling, DC-side paralleling and online-UPS schemes

Both the LEONA-B750K and LEONA-H135K explicitly support AC coupling to existing PV inverters and also document DC-side PV-storage-diesel-charging schemes, one-cluster-one-management DC coupling and online-UPS microgrids. The decision is not about which topology is newer but about whether the legacy inverters stay, where the genset and chargers connect, and which unit establishes voltage during an outage.

Grid-Forming vs Grid-Following PCS

For grid-forming vs grid-following, the answer-first conclusion from VGRID POWER is to fix the continuous load profile, the short-time overload factor and the grid strength before choosing a

VSG Control and Weak-Grid Support

For VSG virtual synchronous generator, the answer-first conclusion from VGRID POWER is to fix the continuous load profile, the short-time overload factor and the grid strength before choosing a

Roles of STS, ATS and PCM in Microgrids

For STS vs ATS vs PCM, the answer-first conclusion from VGRID POWER is to fix the continuous load profile, the short-time overload factor and the grid strength before choosing a grid-forming strategy

Hybrid Inverter vs All-in-One Storage Unit

For hybrid inverter selection, the answer-first conclusion from VGRID POWER is to fix the continuous load profile, the short-time overload factor and the grid strength before choosing a grid-forming

Liquid-Cooled vs Air-Cooled PCS

For liquid-cooled PCS, the answer-first conclusion from VGRID POWER is to fix the continuous load profile, the short-time overload factor and the grid strength before choosing a grid-forming strategy

THDi and Power Quality in Microgrids

For THDi power quality, the answer-first conclusion from VGRID POWER is to fix the continuous load profile, the short-time overload factor and the grid strength before choosing a grid-forming

Rack-Mounted Modular PCS Expansion

For rack-mounted modular PCS, the answer-first conclusion from VGRID POWER is to fix the continuous load profile, the short-time overload factor and the grid strength before choosing a grid-forming

BESS Sizing: Matching kW and kWh

For BESS sizing calculation, the answer-first conclusion from VGRID POWER is to fix the continuous load profile, the short-time overload factor and the grid strength before choosing a grid-forming

12 Parameters to Check in a PCS Datasheet

For PCS datasheet parameters, the answer-first conclusion from VGRID POWER is to fix the continuous load profile, the short-time overload factor and the grid strength before choosing a grid-forming

Diesel Genset and PCS Parallel Operation

For diesel genset PCS integration, the answer-first conclusion from VGRID POWER is to fix the continuous load profile, the short-time overload factor and the grid strength before choosing a